TORDRIX — Your Trusted Gateway to Premium Industrial Door SystemsFire Rated | Cleanroom | Cold Storage | OT | Acoustic | Radiation ShieldedComplied to IS, BS 476, EN, UL & NFPA StandardsPan-India Presence — Gujarat, Maharashtra, RajasthanTORDRIX — Your Trusted Gateway to Premium Industrial Door SystemsFire Rated | Cleanroom | Cold Storage | OT | Acoustic | Radiation ShieldedComplied to IS, BS 476, EN, UL & NFPA StandardsPan-India Presence — Gujarat, Maharashtra, Rajasthan
Request for Quote

Fire Rated Multipurpose Door System

TORDRIX FireShield Multi

Fire Protection Meets Functional Versatility.

TORDRIX FireShield Multi is a dual-purpose door system combining up to 120-minute fire resistance with multi-functional utility for diverse building environments. Featuring intumescent strips, smoke seals, and robust steel construction, it delivers fire compartmentation alongside everyday operational durability for commercial, industrial, and institutional projects.

Commercial & Retail ComplexesIndustrial Plants & WarehousesHospitals & Institutional BuildingsHotels & Convention CentresMixed-Use Developments

Dual-purpose performance. Fire tested. Operationally proven.

TORDRIX FireShield Multi — Fire Rated Multipurpose Door System

Key Advantages

Why TORDRIX FireShield Multi?

FireShield Multi merges fire-rated protection with the operational versatility of a high-performance multipurpose door, eliminating the need for separate door systems.

Up to 120-Minute Fire Resistance

Available in 30, 60, 90, and 120 minute configurations tested to IS 3614, BS 476, and EN 1634 standards.

Intumescent Strip Sealing

Heat-reactive intumescent strips expand to seal door-to-frame gaps, blocking fire and hot gas passage during fire events.

Smoke Seal Integration

Built-in smoke seals restrict cold and hot smoke migration, maintaining escape route visibility and breathability.

Multipurpose Operational Design

Engineered for daily high-traffic use while maintaining fire-rated integrity — suitable as both service and fire barrier doors.

Thermal Insulation Core

High-density mineral wool core provides fire resistance along with thermal insulation for climate-controlled environments.

Standards Complied Construction

Fire performance validated at CBRI under IS 3614, BS 476 Part 22, and EN 1634-1 testing protocols.

Custom Finish Options

Powder-coated RAL finishes and stainless steel cladding options for seamless integration with building interiors.

Access Control Integration

Compatible with electromagnetic locks, proximity readers, and fire alarm hold-open systems for smart building management.

Applications & Industry Use Cases

Where FireShield Multi Performs Best

FireShield Multi is ideal for buildings that need everyday operational doors with built-in fire compartmentation — reducing cost and complexity.

Commercial Complexes

Fire-rated service doors for corridors, utility rooms, and tenant separation walls in offices and retail spaces.

Industrial Facilities

Dual-purpose doors for production floors, storage zones, and utility areas requiring fire compartmentation.

Healthcare Infrastructure

Fire and service doors for hospital corridors, pharmacy stores, and equipment rooms.

Warehouses & Logistics

High-traffic fire-rated access in loading docks, sorting facilities, and storage compartments.

Mixed-Use Developments

Versatile fire-rated doors serving residential, commercial, and parking level transitions.

Technical Specifications

Dual-Function Engineering with Fire-Rated Performance

FireShield Multi doors combine the durability of a multipurpose steel door with fire-rated construction, tested for stability, integrity, and insulation performance.

Material of Construction

Galvanized Steel (GI)

Optional Configuration

Stainless Steel 304/316

Frame Thickness

1.6 mm

Door Leaf (Shutter)

0.8 mm (per skin)

Door Leaf Thickness

46 mm / 54 mm (rating dependent)

Core Material

High-Density Mineral Wool

Non-combustible core providing fire resistance and thermal insulation, rated up to 1000°C.

Hardware & Cleanroom Accessories

  • Fire-Rated Hinges (SS 304)
  • Mortise Lock with Fire-Rated Cylinder
  • Overhead Door Closer (EN 1154)
  • Intumescent Strips
  • Smoke Seals
  • Electromagnetic Hold-Open Device (optional)
  • Panic/Exit Hardware (optional)
  • Drop-Down Seal (optional)
Vision Panel Options
300 × 300 mm250 × 600 mm300 × 900 mm

Fire-rated glass panels with intumescent glazing tape, matched to the door assembly rating.

Standard Door Sizes

Single Door

  • 900 × 2100 mm
  • 1000 × 2100 mm
  • 1200 × 2100 mm
  • 900 × 2400 mm
  • 1200 × 2400 mm

Double Door

  • 1500 × 2100 mm
  • 1800 × 2100 mm
  • 2000 × 2100 mm
  • 1800 × 2400 mm
  • 2400 × 2400 mm

Custom sizes available for non-standard openings and project-specific requirements.

Colour Options (RAL Finishes)

9001

RAL 9001

Cream White

#FDF4E3

9002

RAL 9002

Grey White

#E7EBDA

3020

RAL 3020

Traffic Red

#CC0605

7035

RAL 7035

Light Grey

#D7D7D7

7040

RAL 7040

Window Grey

#9DA1AA

5015

RAL 5015

Sky Blue

#2271B3

Custom RAL colours and wood-grain laminate finishes available on request.

Materials & Performance

Door Materials

  • Galvanized Steel Frame & Leaf
  • High-Density Mineral Wool Core
  • Intumescent Strips & Smoke Seals

Product Gallery

FireShield Multi in Detail

Explore detailed views of the product including construction, hardware, finishes, and installed environments.

FireShield Multi — Front View
FireShield Multi — Interior Detail
FireShield Multi — Hardware Close-up
FireShield Multi — Installation View
FireShield Multi — Side Profile
FireShield Multi — Finish Detail

Performance Comparison

How FireShield Multi Stands Out

FeatureFireShield MultiStandard Multipurpose Door
Fire ResistanceUp to 120 minutes (CBRI tested)No fire rating
Dual FunctionalityFire barrier + everyday service doorService function only
Smoke ProtectionIntegrated intumescent strips & smoke sealsNo smoke control
Core ConstructionHigh-density mineral wool (non-combustible)Honeycomb or foam core
ComplianceComplied with IS 3614, BS 476, EN 1634No fire test documentation

Fire ratings based on CBRI test reports. Actual performance depends on complete assembly configuration including frame, hardware, and seals.

Architect & Specifier Guide

Designed for Architects, MEP Consultants & Fire Engineers

FireShield Multi simplifies door scheduling by combining fire-rated and multipurpose specifications into a single door system — reducing procurement complexity and improving compliance.

  • Single door system serving fire compartmentation and daily operational needs
  • Fire ratings from 30 to 120 minutes complied with IS, BS, and EN standards
  • Integrated intumescent and smoke seal systems in a multipurpose form factor
  • Compatible with fire alarm hold-open devices and BMS integration
  • Reduces door schedule complexity in mixed-use and commercial projects

Fire test reports, specification sheets, and AutoCAD drawings available for project planning.

Product Brochure

Access detailed specifications, drawings, and installation guidelines for your project.

Download Technical Datasheet

Product Information

Frequently Asked Questions

Common questions about TORDRIX FireShield Multi

Simplify Fire Safety with FireShield Multi

Specify TORDRIX FireShield Multi for projects that need fire-rated protection and multipurpose functionality in a single, tested door system.

Our engineering team responds within 24 hours with technical specifications, fire test reports, and project recommendations.