Fire Rated Multipurpose Door System
TORDRIX FireShield Multi
Fire Protection Meets Functional Versatility.
TORDRIX FireShield Multi is a dual-purpose door system combining up to 120-minute fire resistance with multi-functional utility for diverse building environments. Featuring intumescent strips, smoke seals, and robust steel construction, it delivers fire compartmentation alongside everyday operational durability for commercial, industrial, and institutional projects.
Dual-purpose performance. Fire tested. Operationally proven.

Key Advantages
Why TORDRIX FireShield Multi?
FireShield Multi merges fire-rated protection with the operational versatility of a high-performance multipurpose door, eliminating the need for separate door systems.
Up to 120-Minute Fire Resistance
Available in 30, 60, 90, and 120 minute configurations tested to IS 3614, BS 476, and EN 1634 standards.
Intumescent Strip Sealing
Heat-reactive intumescent strips expand to seal door-to-frame gaps, blocking fire and hot gas passage during fire events.
Smoke Seal Integration
Built-in smoke seals restrict cold and hot smoke migration, maintaining escape route visibility and breathability.
Multipurpose Operational Design
Engineered for daily high-traffic use while maintaining fire-rated integrity — suitable as both service and fire barrier doors.
Thermal Insulation Core
High-density mineral wool core provides fire resistance along with thermal insulation for climate-controlled environments.
Standards Complied Construction
Fire performance validated at CBRI under IS 3614, BS 476 Part 22, and EN 1634-1 testing protocols.
Custom Finish Options
Powder-coated RAL finishes and stainless steel cladding options for seamless integration with building interiors.
Access Control Integration
Compatible with electromagnetic locks, proximity readers, and fire alarm hold-open systems for smart building management.
Applications & Industry Use Cases
Where FireShield Multi Performs Best
FireShield Multi is ideal for buildings that need everyday operational doors with built-in fire compartmentation — reducing cost and complexity.
Commercial Complexes
Fire-rated service doors for corridors, utility rooms, and tenant separation walls in offices and retail spaces.
Industrial Facilities
Dual-purpose doors for production floors, storage zones, and utility areas requiring fire compartmentation.
Healthcare Infrastructure
Fire and service doors for hospital corridors, pharmacy stores, and equipment rooms.
Warehouses & Logistics
High-traffic fire-rated access in loading docks, sorting facilities, and storage compartments.
Mixed-Use Developments
Versatile fire-rated doors serving residential, commercial, and parking level transitions.
Technical Specifications
Dual-Function Engineering with Fire-Rated Performance
FireShield Multi doors combine the durability of a multipurpose steel door with fire-rated construction, tested for stability, integrity, and insulation performance.
Material of Construction
Galvanized Steel (GI)
Optional Configuration
Stainless Steel 304/316
Frame Thickness
1.6 mm
Door Leaf (Shutter)
0.8 mm (per skin)
Door Leaf Thickness
46 mm / 54 mm (rating dependent)
Core Material
High-Density Mineral Wool
Non-combustible core providing fire resistance and thermal insulation, rated up to 1000°C.
Hardware & Cleanroom Accessories
- Fire-Rated Hinges (SS 304)
- Mortise Lock with Fire-Rated Cylinder
- Overhead Door Closer (EN 1154)
- Intumescent Strips
- Smoke Seals
- Electromagnetic Hold-Open Device (optional)
- Panic/Exit Hardware (optional)
- Drop-Down Seal (optional)
Fire-rated glass panels with intumescent glazing tape, matched to the door assembly rating.
Standard Door Sizes
Single Door
- 900 × 2100 mm
- 1000 × 2100 mm
- 1200 × 2100 mm
- 900 × 2400 mm
- 1200 × 2400 mm
Double Door
- 1500 × 2100 mm
- 1800 × 2100 mm
- 2000 × 2100 mm
- 1800 × 2400 mm
- 2400 × 2400 mm
Custom sizes available for non-standard openings and project-specific requirements.
Colour Options (RAL Finishes)
RAL 9001
Cream White
#FDF4E3
RAL 9002
Grey White
#E7EBDA
RAL 3020
Traffic Red
#CC0605
RAL 7035
Light Grey
#D7D7D7
RAL 7040
Window Grey
#9DA1AA
RAL 5015
Sky Blue
#2271B3
Custom RAL colours and wood-grain laminate finishes available on request.
Materials & Performance
Door Materials
- Galvanized Steel Frame & Leaf
- High-Density Mineral Wool Core
- Intumescent Strips & Smoke Seals
Product Gallery
FireShield Multi in Detail
Explore detailed views of the product including construction, hardware, finishes, and installed environments.






Performance Comparison
How FireShield Multi Stands Out
| Feature | FireShield Multi | Standard Multipurpose Door |
|---|---|---|
| Fire Resistance | Up to 120 minutes (CBRI tested) | No fire rating |
| Dual Functionality | Fire barrier + everyday service door | Service function only |
| Smoke Protection | Integrated intumescent strips & smoke seals | No smoke control |
| Core Construction | High-density mineral wool (non-combustible) | Honeycomb or foam core |
| Compliance | Complied with IS 3614, BS 476, EN 1634 | No fire test documentation |
Fire ratings based on CBRI test reports. Actual performance depends on complete assembly configuration including frame, hardware, and seals.
Architect & Specifier Guide
Designed for Architects, MEP Consultants & Fire Engineers
FireShield Multi simplifies door scheduling by combining fire-rated and multipurpose specifications into a single door system — reducing procurement complexity and improving compliance.
- Single door system serving fire compartmentation and daily operational needs
- Fire ratings from 30 to 120 minutes complied with IS, BS, and EN standards
- Integrated intumescent and smoke seal systems in a multipurpose form factor
- Compatible with fire alarm hold-open devices and BMS integration
- Reduces door schedule complexity in mixed-use and commercial projects
Fire test reports, specification sheets, and AutoCAD drawings available for project planning.
Product Brochure
Access detailed specifications, drawings, and installation guidelines for your project.
Download Technical DatasheetProduct Information
Frequently Asked Questions
Common questions about TORDRIX FireShield Multi
Simplify Fire Safety with FireShield Multi
Specify TORDRIX FireShield Multi for projects that need fire-rated protection and multipurpose functionality in a single, tested door system.
Our engineering team responds within 24 hours with technical specifications, fire test reports, and project recommendations.